Skip to content

PVC Welding Curtains: What EN 25980 and ISO 25980 Actually Require

November 4, 2026 kezhibo Company News, News
Tensile test machine testing coated fabric in the laboratory

Why workshops still reach for PVC welding curtains

An open welding arc can sting unprotected eyes three metres away within seconds, and ejected spatter lands at over 1500°C. A PVC welding curtain solves one narrow problem: in an open bay it blocks the near- and far-ultraviolet and blue light in the arc, catches sparks and fume, yet lets a supervisor or a collaborative robot see the work without a helmet. It is a flexible vinyl barrier, not a substitute for personal protection. That distinction matters more now that cobot welding cells put a robot arm a few feet from a human operator, where a hard guard would block the very line of sight the cell needs.

What the standards actually test

A green curtain is not automatically safe, and a darker curtain is not automatically a higher shade. The required designation comes from the arc process, current range, duty cycle, viewing distance and workshop layout. Europe and Australia run on EN 25980 and ISO 25980, which declare UV attenuation and spectral transmittance for transparent welding screens. EN 1598 and North America’s AWS F2.3 set the broader screen requirements, while US buyers often ask for NFPA 701 flame resistance. Clearway’s ScreenFlex strip curtain is stated as 100% phthalate free, rated -15°C to 50°C, and compliant with EN 1598 / AWS F2.3 / ISO 25980 (source: clearwayonline.ie). Welding & Welder’s green PVC curtain declares EN25980 conformance, a 200°C maximum service temperature, and a recommended 1.5 m standoff from the arc (source: weldingandwelder.com).

Material build: thickness, temperature, optical grade

Transparent welding-grade PVC strips run about 0.35-2 mm; Riltik’s transparent green panel is 14 mil (roughly 0.36 mm) and treated water- and mildew-resistant (source: riltik.com). Continuous service is typically 50-70°C for transparent strips, with short peaks far higher depending on the coating. Olympus separates four different failure conditions in its spec table – continuous service temperature, short-duration peak, coating limit and base-cloth limit – and warns that one number does not describe all of them (source: olympustechnologies.co.uk).

The colour is functional, not decorative. Green or bronze tints filter the hazardous part of the arc spectrum while preserving enough visibility to watch the weld pool. Transparency is not a shade rating; judge a screen by the manufacturer’s declared spectral transmittance, not by how dark it looks. Cameras and remote viewing, where available, reduce the need for anyone to watch the arc through the enclosure at all.

Where they earn their keep

Robotic and cobot welding cells, MIG/MAG/TIG bay screens, grinding and spray booths, and movable enclosures in ship repair and maintenance. Strip curtains assemble fast, which suits lines whose layout changes weekly. They also serve as perimeter screens and viewing windows where a solid wall would trap fume or block material flow.

Specifying the right curtain

  1. Record the process, peak current, duty cycle and viewing distance before choosing a grade.
  2. Ask transparent sections for EN ISO 25980 evidence and spectral data; name the textile test method and class for opaque layers.
  3. Confirm continuous and peak temperature limits for coating, base cloth, seams and fasteners.
  4. Keep at least 1.5 m clearance and check floor gaps, cable penetrations and extraction ducts.
  5. Inspect for holes, embrittlement and seam damage every shift; keep declarations and certificates on file.

One practical rule from integrators: a fire-rated fabric or EN ISO 25980 curtain is one risk-control component, not a complete safeguarding system. The validated cell still needs fixed guarding, interlocks and monitored stops under BS EN ISO 10218-2 and PUWER. A soft cover cannot prevent crushing or trapping unless another protective measure does.

Common specification mistakes

Two errors show up repeatedly in weld-cell audits. The first is buying on colour: a darker strip is not a higher shade, and a curtain that looks ‘safer’ may still carry no EN ISO 25980 declaration or spectral data. The second is ignoring the standoff distance – a 200°C rating only holds at a 1.5 m gap, and a curtain pushed against the bench absorbs spatter it was never meant to touch. Budget for spares: transparent strips yellow and craze under UV, so a replaceable strip system beats a bonded panel when the cell runs double shifts. For cobot cells, confirm the cover cannot foul the arm, torch neck or teach-pendant cable, and remember a fire-rated fabric is one control inside a validated cell, not the whole safeguarding system. Keep the declarations, certificates and replacement records on file; they are what turns a curtain into a defensible risk control.

Frequently asked questions

Q: Can a PVC welding curtain replace a welding helmet?
No. It is a cell divider and arc-light filter; the operator still needs a compliant helmet, goggles or face shield. Direct viewing through the curtain is governed by the manufacturer’s declared use and the risk assessment.

Q: What temperature can a PVC welding curtain handle?
Transparent strips are good for about 50-70°C continuous use; many carry a ~200°C maximum service temperature at a 1.5 m standoff. Direct contact with hot workpieces destroys the material, and spatter size, slag and torch faults all change the required rating.

Q: Are phthalate-free welding curtains available?
Yes. Products such as Clearway ScreenFlex are stated as 100% phthalate free and meet EN 1598, AWS F2.3 and ISO 25980, with flexibility down to -15°C.